TSW-10 Turbidity Sensor The TSW-10 module measures the turbidity (amount of suspended particles) of the wash water in washing machines and dishwashers. An optical sensor for washing machines is a measuring product for a turbid water density or an extraneous matter concentration using the refraction of wavelength between photo transistor and diode. By using an optical transistor and optical diodes, an optical washing machine sensor measures the amount of light coming from the source of the light to the light receiver, in order to calculate water turbidity. Amphenol Advanced SensorsTheory of Operation The sensor operates on the principle that when light 22 0.4 Photo TR DIODE 5.7 0.1 is passed through a sample of water, the amount of (Light receiving part) (Light emitting part) light transmitted through the sample is dependent on the amount of soil in the water. As the soil level increases, the amount of transmitted light decreases. The turbidity sensor measures the amount of transmitted light to determine the turbidity of the wash water. These turbidity measurements are supplied to the washer controller, which makes decisions on how long to wash in all the cycles. These decisions are made based on a comparison between clean water measurements (taken at the beginning of the wash cycle) and the wash water turbidity Upper Base Plane measurement taken at the end of each wash cycle. By measuring the turbidity of the wash water, the washing machine can conserve energy on lightly soiled loads by only washing as long as necessary. 30 This will result in energy savings for the consumer. Specifications Part Number 1 3 2 TSW-10 Rated Voltage Turbidity Sensor DC 5V (between No 1 & Ground) VCC + (+5V) Voltage Differential DIODE 1 (Light emitting part) 1.3V 20% Pin Test Method After testing voltage in water (0 NTU), 2 Output Photo TR Pin 3 voltage test in water (1000 NTU) (Light receiving part) Pin (Turbidity level Calibration -> Master NTU standard Ro 4.7KW Ri 470W liquid ) (Voltage between No 2 pin & Ground) GND Operating Temperature Range -30C ~ 80C 5.0 Storage Temperature Range -10C~ 80C 4.5 Rated Current 4.0 Max. 30 mA 3.5 Insulation Resistance Min 100 M by 500V DC 3.0 Application Section 2.5 Detecting the turbidity degree of water 2.0 1.5 0 500 1000 1500 2000 NTU www.amphenol-sensors.com Amphenol 2014 Amphenol Corporation. All Rights Reserved. Specifications are subject to change without notice. Other company names and product names used in this document are the registered trademarks or Advanced Sensors trademarks of their respective owners. AAS-920-479B-03/2014 V (Voltage) 34 0.4