Programmable Digital Timer Digital 7-Segment display Supply Voltage range of 110-240 VAC Input Signal Sensing range of 85-265 VAC/100-265 VDC & 20-60 VAC/DC Inbuilt library of 33 functions covering majority applications Easy steps to program customized functions Suitable for Panel and Base/DIN mounting Two separate Channel outputs with selectable Timer modes Wide timing range - 0.1 Sec. to 999 Days Tamper proof with key lock feature Provision to edit Preset time during Run time Provision to save two independent functional Profiles (P1 & P2) Ordering Information Cat. No. Description V7DFTS3 110 - 240 VAC, Multi Function Digital Timer - Eliro (33 Functions), 2 C/O V7DDSS3 110 - 240 VAC, Multi Function Digital Timer - Eliro (33 Functions), 2 C/O, 11 Pin Universal socket 10 Programmable Digital Timer Cat. No. V7DFTS3 V7DDSS3 Parameters Timer Description Programmable Multi Function Digital Timer Default Functions 1) On delay 17) Impulse on energizing 2) On delay constant supply type 2 18) Impulse on/off 3) On delay constant supply type 3 19) Accumulative delay on signal 4) On delay (control switch resettable) 20) Accumulative delay on inverted signal 5) Signal on delay 21) Accumulative impulse on signal 6) Inverted signal on delay 22) Leading edge impulse 7) Inverted signal on delay type 2 23) Leading edge impulse 2 8) Signal off delay 24) Trailing edge impulse 9) Off delay const. supply type 2 25) Trailing edge impulse 2 10) Cyclic on/off 26) Delayed impulse 11) Cyclic off/on 27) Delayed impulse type 2 12) Asymmetric cycle pulse start 28) Delayed pulse (constant supply) 13) Asymmetric recycler pulse start type 2 29) Delayed pulse (remote trig.) 14) Signal on off delay 30) Delayed pulse (const. supply type 1) 15) Signal on off delay type 2 16) Signal off/on (new) 31) On pulse (control switch resettable) 32) On pulse (supply reset)mode 33) Leading edge bi-stable or step relay Supply Voltage ( ) 110 - 240 VAC Supply Variation -20% to +10% (of ) Frequency 47-63 Hz Power Consumption (Max.) 9 VA Timing Range 0.1s to 999 days Reset Time/Initiate Time 200 ms (Max.) / 100 ms (Max.) Input Signals/Signal Isolation High Range: 85-265V AC/ 100-265V DC, Low Range: 24-60V AC/DC / 2 KV Signal Sensing Time/ Wait Period 50ms. (max.) / 100ms Power On & for signal based modes only. Timing Accuracy 0.01% Relay Output 2 C/O Contact Rating 5A for NO & 3A for NC 250VAC/30VDC (Resistive.) Output 5 Electrical Life 1x10 6 Mechanical Life 5x10 AC - 15 250V AC/2A, Cos = 0.6, 85c, 100000 Operations. Utilization Category DC - 13 Ue rated voltage V 24 Ie rated current A 2.0. Operating Temperature -5 C to +55 C Storage Temperature -10 C to +60 C Humidity (Non Condensing) 95% (Rh) LED Indication SV (Red) - Set Value P1/P2 (Red) -P1 Running Up/Down (Red)-Up Counting SG (Green)- Signal Present OP1 (Red)-Relay OP1 ON OP2 (Red)-Relay OP2 ON Enclosure IP 30 for Housing & front Facial and IP 20 for Terminals Dimension (W x H x D) (in mm) 48 X 48 X 92.5 Weight (unpacked) 160 g Mounting Panel / Flush Mountable Base / DIN Rail with 11 Pin Universal socket Certification RoHS Compliant Degree of Protection IP 20 for Terminals, IP 30 for Enclosure EMI / EMC Harmonic Current Emissions IEC 61000-3-2 ESD IEC 61000-4-2 Radiated Susceptibility IEC 61000-4-3 Electrical Fast Transients IEC 61000-4-4 Surges IEC 61000-4-5 Conducted Susceptibility IEC 61000-4-6 Voltage Dips & Interruptions (AC) IEC 61000-4-11 Voltage Dips & Interruptions (DC) IEC 61000-4-29 Conducted Emission CISPR 14-1 Radiated Emission CISPR 14-1 Environmental Cold Heat IEC 60068-2-1 Dry Heat IEC 60068-2-2 Vibration IEC 60068-2-6 Repetitive Shock IEC 60068-2-27 Non-Repetitive Shock IEC 60068-2-27 11