X-On Electronics has gained recognition as a prominent supplier of DHR 400 C10 interface - specialised across the USA, India, Europe, Australia, and various other global locations. DHR 400 C10 interface - specialised are a product manufactured by Lem. We provide cost-effective solutions for interface - specialised, ensuring timely deliveries around the world.

DHR 400 C10 Lem

DHR 400 C10 electronic component of Lem
Images are for reference only
See Product Specifications
Part No.DHR 400 C10
Manufacturer: Lem
Category:Interface - Specialised
Description: Current Transducer,400A, 0-10V O/P
Datasheet: DHR 400 C10 Datasheet (PDF)
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 532.9584 ea
Line Total: USD 532.96

Availability - 0
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 07 Jun to Thu. 13 Jun

MOQ : 1
Multiples : 1
1 : USD 532.9584
5 : USD 490.0918
10 : USD 483.9737

     
Manufacturer
Product Category
Brand
Sensor Output
Supply Voltage Dc Min
Supply Voltage Dc Max
Current Measuring Range Dc
Current Measuring Range Ac
Response Time
Accuracy
Product Range
Svhc
Conductor Diameter Max
Current Consumption
Current Max
Current Range Ac
Current Range Dc
External Depth
External Length / Height
External Width
Fixing Hole Diameter
Flammability Rating
Frequency Max
Frequency Min
Ip / Nema Rating
Load Current Max
Operating Frequency Range
Operating Temperature Max
Operating Temperature Min
Output Type
Output Voltage
Output Voltage Min
Supply Current
Supply Voltage Range Dc
Transducer Function
Weight
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Part-Description
Stock Image CKSR 25-NP
SENSOR CURRENT FLUX 25A AC/DC
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image CAS 50-NP
SENSOR CURRENT FLUX 50A AC/DC
Stock : 2
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image AT150B420L
CURRENT TRANSDUCER, 150A, CURRENT O/P
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image AT100B420L
CURRENT TRANSDUCER, 100A, CURRENT O/P
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image DHR 600 C10
Current Transducer,600A, 0-10V O/P
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image DHR 1000 C420
Current Transducer,1000A, 4-20Ma O/P
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image AT20B420L
CURRENT TRANSDUCER, 20A, CURRENT O/P
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image AT50B10
CURRENT TRANSDUCER, 50A, VOLTAGE O/P
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image HAS300-S
Current Sensors Through Hole RoHS
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image LAH100-P
Current Sensors Through Hole RoHS
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Image Part-Description
Stock Image NCN8024DTBR2G
ON Semiconductor Interface - Specialized SMART CARD IC 3ST 8INPUT
Stock : 2465
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 27460
27460 SLOTTED BIT 3MM
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SP337EUCY-L
Interface - Specialised RS232/422/RS485 Transceiver Multi
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image NCN8025MTTBG
Interface - Specialized SMART CARD IC
Stock : 2
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image DHR 1000 C420
Current Transducer,1000A, 4-20Ma O/P
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SP338EER1-L
SP338E Series 3.3 V or 5 V 20 Mbps RS-232/RS-485/RS-422 Transceiver - QFN-40
Stock : 1386
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image TDA8035HN/C1/S1J
Interface - Specialized Smart card interface
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image CH351Q
Interface - Specialized LQFP-64_7x7x04P RoHS
Stock : 230
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image CH7307C-DEF
Interface - Specialized LQFP-48 RoHS
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SP336ECY-L
Interface - Specialized 4 Tx/Rx Programmable RS232/485/422 Serial
Stock : 95
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
We are delighted to provide the DHR 400 C10 from our Interface - Specialised category, at competitive rates not only in the United States, Australia, and India, but also across Europe and beyond. A long established and extensive electronic component distribution network has enhanced our global reach and dependability, ensuring cost savings through prompt deliveries worldwide. Client satisfaction is at the heart of our business, where every component counts and every customer matters. Our technical service team is ready to assist you. From product selection to after-sales support, we strive to deliver a seamless and satisfying experience. Are you ready to experience the best in electronic component distribution? Contact X-ON Electronics today and discover why X-On are a preferred choice for the DHR 400 C10 and other electronic components in the Interface - Specialised category and beyond.

AC/DC Current transducer DHR-C10 I = 100..1000 A PN The transducer for the electronic measurement DC & distorted AC waveforms current, with galvanic isolation between the primary (High power) and the secondary circuits (Electronic circuit). True RMS 0-10V voltage output. Electrical data Features Primary Nominal Primary AC Current Analogue Output Type DC & AC Current Max. Peak Value Signal VFD and SCR waveforms current I (A.t.RMS) I (A) V (VDC) PN P OUT measurement 100 600 0-10 DHR 100 C10 200 600 0-10 DHR 200 C10 True RMS output 300 1000 0-10 DHR 300 C10 Panel mounting 400 1000 0-10 DHR 400 C10 Eliminates insertion loss 500 1800 0-10 DHR 500 C10 600 1800 0-10 DHR 600 C10 1000 1800 0-10 DHR 1000 C10 Advantages R Load resistance 10 k L V Supply voltage +20 .. 50 V DC Large aperture for cable up to C I Current Consumption 30 mA C 32mm Limitation of voltage output (0-10V) < 14 V High isolation between primary and Overloaded input current (Ampere Turns) 30000 A.t secondary circuits Easy to mount Accuracy-Dynamic performance data X Accuracy I , T = 25C (without offset) < 1 % of I PN A PN e Linearity (1% of I .. I ) < 1.0 % of I Applications L PN PN PN V Electrical offset voltage, T = 25C < 1.0 % of I OE A PN VFD Controlled Loads: V Thermal drift of V (-20..+60 C) 1 mV/K OT OE VFD output indicates how the motor (-40..+70 C) 2.0 mV/K and attached load are operating. TCe Thermal drift of the gain (% of reading) 0.1 %/K G SCR Controlled Loads: t Response time 90% of I < 150 m s r P f Frequency bandwidth (1%) DC 20..6000Hz Acurate measurement of phase angle fired or burst fired (time General data proportioned) SCRs. Current measurement gives faster T Ambient operating temperature -40 .. +70 C A response than temperature T Ambient storage temperature -40 .. +85 C S m Mass 260 g measurement. Protection type IP20 Switching Power Supplies and UL94 classification V0 Electronic Ballasts: True RMS sensing is the most accurate way to measure power supply or ballast input power. Notes : Installation and maintenance should be done with power supply disconnected. The operator must have accrediation to install this material. The users must take care of all protection gurantee against electrical shock. 050526/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 1/3 LEM Components www.lem.comCurrent Transducer DHR-C10 Isolation characteristics V Rated Voltage 1000 V b with IEC 61010-1 acc. to the 61326 standards and following conditions : - Single insulation - Over voltage category CAT III - Pollution degree PD2 - None uniform field V R.m.s. voltage for AC insulation test, 50Hz, 1min 5 kV d dCp Creepage distance 11 mm dCl Clearance distance 11 mm CTI Comparative tracking index (Group I) 600 Notes : Output polarity with DC input Output in V 10 -Ipn +Ipn 0 050526/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 2/3 LEM Components www.lem.com

Tariff Desc

8542.39.23 No ..Linear/analogue and peripheral integrated circuits, timers, voltage regulators, A/D and D/A converters, telecommunication and modem integrated circuits, other than board level products Free

Electronic integrated circuits- Processors and controllers, whether or not combined with memories, converters, logic circuits, amplifiers, clock and timing circuits, or other circuits
Beijing Lem Electronics
BEIJING LEM ELECTRONICS LTD.
LEM USA Inc.

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted