Surge arrester 2-electrode arrester Series/Type: A80-C90XSMD Ordering code: B88069X1630T602 Date: 2016-02-03 Version: 12 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers Please fill in the table and then change the color towhit. This ensures that the table disappears (invisible) for the customer PDF. Don t change formatting when entering or pasting text in the table and don t add any cell or line in and to it Identification/Classification 1 Surge arrester (header 1 + top left bar): Identification/Classification 2 2-electrode arrester (header 2 + bottom left header bar): Ordering code: (top right header bar) B88069X1630T602 Series/Type: (bottom right header bar) A80-C90XSMD Preliminary data (optional): Department: PPD AB PD / PPD AB PM Date: 2016-02-03 Version: 1 2 EPCOS AG 2016. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS prior express consent is prohibited. EPCOS AG is a TDK Group Company. Surge arrester B88069X1630T602 2-electrode arrester A80-C90XSMD Features Applications Standard size Consumer electronic Fast response time Alarm systems Very high current rating Stable performance over life Very low capacitance High insulation resistance Excellent SMD handling RoHS-compatible Electrical specifications 1) 2) DC spark-over voltage 90 V Tolerance 20 % Min. V 72 Max. V 108 Impulse spark-over voltage at 100 V/s - for 99% of measured values < 500 V - typical values of distribution < 450 V at 1 kV/s - for 99% of measured values < 600 V - typical values of distribution < 550 V Service life 10 operations 50 Hz, 1 s 20 A 1 operation 50 Hz 0.18 s (9 cycles) 100 A 10 operations 5 (+) & 5 (- ) 8/20 s 20 kA 1 operation 8/20 s 25 kA 1 operation 10/350 s 5 kA 300 operations 10/1000 s 100 A Insulation resistance at 50 V > 10 G DC Capacitance at 1 MHz < 1.5 pF Arc voltage at 1 A ~ 10 V Glow to arc transition current < 0.5 A Glow voltage ~ 60 V Weight ~ 1.5 g Operation and storage temperature C - 40 ... +125 Climatic category (IEC 60068-1) 40/125/21 90 YY O Marking, blue negative 90 - Nominal voltage YY - Year of production O - Non radioactive Certification UL 497B (E163070) 1) At delivery AQL 0.65 level II, DIN ISO 2859 2) In ionized mode Terms in accordance with ITU-T Rec. K.12, IEC 61663-2 and IEC 61643-311 PPD AB PD / PPD AB PM 2016-02-03 Please read Cautions and warnings and Page 2 of 5 Important notes at the end of this document.